The Cemco-Major Model 685E
Liquid Level Transmitter is an electro-mechanical level control device, which accomplishes three (3) main functions.
These are remote indication, local liquid level indication, and hi- to adjustable switch outputs. The Model 685E
continuously indicates the liquid level and transmits a proportional signal.
Features:
- Complementary Adjustments - Zero and span adjustments at the transmitter. The range adjustment at the transmitter compensates for various liquid gravities.
- Easy To Read - Scale reads the same as a hand tank gauge making it unnecessary to convert PSIG or head into inches or feet of water to get correct
reading. Special Scales are available.
- Integral Weatherproof And Explosion Proof Enclosures - All mechanical working parts are housed in a weather proof enclose, while the transmitter and
switches are housed in an explosion proof housing. Housings are integrally cast together.
- Corrosion Resistant - Majority of parts are stainless steel or Teflon, with remaining parts being anodized, cadmium plated, etc.
- Long Life - All bearing are Tefloned, delrin, or moly disulphide baked on dry film lubricated stainless steel.
- Pulsation Dampening - A snubber, or pulsation dampener, is available to reduce line surges if the unit is installed on a pump suction line.
Specifications:
- Vessel Inlet connection: 2” NPT; 2”-150# ASR R.F. FLANGE or 2” GROOVED, Cad Plated Ductile
- Transmitter Housing Front: Acrylic Window with Stainless Steel Bezel Frame * Diaphragm: Buna-N, an elastomer
- Range (Vessel Height): 3 feet thru 60 feet
- Operating Pressure: Atmospheric Vessel, Liquid Head Pressure
- Transmitter Output: 4-20 mADC
- Transmission: Four (4) wires
- Supply Voltage (at transmitter): 120 Vac, 60 cycle, 1 phase
- Electrical Switches: SPDT Microswitch, 10 Amp at 125 or 250 VAC, 1/2 Amp at 125 VDC, 1/4 Amp at 250 VDC, 4 Amp at 125 VAC Induction
- Electrical Connection: 1/2” Female Pipe thread. 3/4” Female Pipe thread optional. Suitable for use in Class I, Group C and D; Class II, Groups E, F, G
Hazardous locations
Request more information on a
685E Liquid Level Transmitter today!
|