The OSECO VAPRO and
POSIPRO rupture disks are economical alternatives for applications requiring extremely low positive pressure protection. The VAPRO and POSIPRO
rupture disks are designed to provide protection for pressures starting as low as 1” of water column. The VAPRO rupture disk
protects against implosion of a vessel, and the POSIPRO rupture disk protects against overpressure.
VAPRO Rupture Disk The VAPRO rupture disk is a dual acting disk that can protect from implosion at
extremely low pressure and can also provide protection from overpressure conditions. The VAPRO rupture disk consists of a perforated 316 stainless steel
top section, a Teflon seal, and a Teflon or 316 stainless steel girdle. If the VAPRO rupture disk is
never subject to any positive pressure a 316 stainless steel support ring can be provided in place of the perforated metal top section.
VAPRO Holder The VAPRO rupture disk is used with either the type VRDI or VRDS rupture disk
holder (see above photo). The VRDI holder is a reduced diameter insert type holder and is designed to bolt between and fit within the bolt circle of standard ANSI pipe
flanges. The VRDS rupture disk holder is a sanitary style holder and is designed to be
used with sanitary quick-release clamps. Standard materials for the VRDI and VRDS are carbon steel and 316 stainless steel
. Precision knifeblades are welded in the inlet of the holder. Standard knifeblade material is 17-7 PH and 300 series stainless steel as an option.
How The VAPRO Works The VAPRO operates over a range of 6 inches of water column in the vacuum
direction. As a vacuum or negative pressure is pulled the girdle and seal reverse. The
girdle passes the knifeblades and the seal is punctured and opened within a maximum of 6 inches of water column of the stamped minimum vacuum pressure. The perforated
metal top section remains unaltered and flow through the perforations relieves the vacuum condition. Systems can operate to within 1 inch of water column of the
minimum requested puncture pressure up to 10 inches of water column, and up to 90% of the minimum requested puncture pressure above 10 inches of water column.
When overpressure occurs the perforated metal top section relieves in the forward direction. Systems can operate to within 80% of the stamped positive pressure of the
VAPRO rupture disk. The rupture tolerance for the perforated metal top section is plus
or minus 2 psig for pressures 40 psig and lower, and plus or minus 5% for pressures greater than 40 psig.
POSIPRO Rupture Disk The POSIPRO rupture disk is a dual acting disk that can protect from extremely low
overpressure conditions and can also provide protection from vacuum. The POSIPRO rupture disk consists of a Teflon or 316 stainless steel
girdle, a Teflon seal, and a 316 stainless steel perforated vacuum support. If the POSIPRO rupture disk is never subject to any vacuum pressure a
316 stainless steel support ring can be provided in place of the perforated metal vacuum support.
POSIPRO Holder The POSIPRO rupture disk is used with either the type POSI or POSS rupture disk
holder. The POSI holder is a reduced diameter insert type holder and is designed to
bolt between and fit within the bolt circle of standard ANSI pipe flanges. The POSS
rupture disk holder is a sanitary style holder and is designed to be used with sanitary quick-release clamps. Standard materials for the POSI and POSS
are carbon steel and 316 stainless steel. Precision knifeblades are welded in the outlet of the holder. Standard knifeblade material is 17-7 PH
and 300 series stainless steel as an option.
How The POSIPRO Works The POSIPRO operates over a range of 6 inches of water column in the positive
direction. As a positive pressure occurs the girdle and seal reverse. The girdle passes
the knifeblades and the seal is punctured and opened within a maximum of 6 inches of water column of the stamped minimum positive pressure. The perforated metal vacuum
support remains unaltered and flow through the perforations relieves the overpressure condition. Systems can operate to within 1 inch of water column of the minimum
requested puncture pressure up to 10 inches of water column, and up to 90% of the minimum requested puncture pressure above 10 inches of water column.
When vacuum occurs the perforated metal vacuum support can be designed to relieve in the vacuum direction, or can be designed to withstand full vacuum. Systems can
operate to within 80% of the stamped vacuum pressure of the POSIPRO rupture disk.
The rupture tolerance for the perforated metal vacuum support is plus or minus 2 psig
for pressures 40 psig and lower, and plus or minus 5% for pressures greater than 40 psig.
Burst Disk Alarm Sensors The OSECO type LPSS and LPSF burst disk alarm sensors provide an immediate
signal when a VAPRO or POSIPRO rupture disk has burst to relieve a vacuum or
overpressure condition. Upon rupture of the bursting disk, the disk alarm circuit is opened by the flowing media. The LPSS and LPSF
burst disk sensors are designed to open at pressure differential of 3 inches of water column or less. Both the LPSF and LPSS
sensors are designed to be installed downstream of the VAPRO or POSIPRO rupture disk. The LPSF
sensor bolts between raise faced ANSI pipe flanges. The LPSS sensor is designed to be used with sanitary quick-release clamps.
See the Min/Max and other charts for the VAPRO and POSIPRO Rupture Disks
Request more information on a VAPRO or POSIPRO rupture disk today!
|